Configure mkanalysis-sess
The first step in the first-level analysis is to configure analyses and contrasts. This step describes what preprocessing stages should have been run as well as the parameters needed to construct a design matrix (no data are analyzed yet). This is done with mkanalysis-sess.
A good way to make it clear how you are configuring your analysis is to declare important parameters as shell environment variables, and then use them when calling mkanalysis-sess:
SMOOTHING=6; #FWHM smoothing kernel; rule of thumb is 2 x VoxelSize REFEVENTDUR=0.8; #How long are the events? TR=2.0; #What is the TR NCONDITIONS=3; #How many conditions in the par files SURFACE=self; #generally valid options are 'self' or 'fsaverage' HEMIS=( lh rh ); #for automatically looping over both hemispheres PARFILE=LDT.par; #What's the name of the .par files in your bold/ directories? SKIPS=4; #If you wish to drop the first n volumes, set to some value other than 0 ANROOT="LDT.sm" #base name for the analysis directories
for hemi in "${HEMIS[@]}"
do
mkanalysis-sess \
-fsd bold \
-surface ${SURFACE} ${hemi} \
-fwhm ${SMOOTHING} \
-event-related \
-paradigm ${PARFILE} \
-nconditions ${NCONDITIONS} \
-timewindow 24 \
-spmhrf 2 \
-polyfit 2 \
-mcextreg \
-TR ${TR} \
-nskip ${SKIPS} \
-refeventdur ${REFEVENTDUR} \
-analysis ${ANROOT}${SMOOTHING}.${hemi} \
-per-run -force
done
The above code could be saved as a script in your ~/bin directory (e.g., mkanalysis.sh) and modified as required for different datasets or parametric choices.
This step creates analysis directories in your $SUBJECTS_DIR containing single files that contain all the information needed for the next step.